Tray

RFID trays are used to track inventory and transactions. It's sleek, rugged form factor and ease of install allow it to be used in a wide variety of environments where a RFID read point is desired. Common applications include tracking two-bin kanban systems for consumable inventory, or as a check-in/check-out station.

Name Description Data Type Min Max Default
AntennaTxPower The dB transmit power of all of the antennas. Int 15 23 23
AutoUpdate Firmware auto update enable. Bool 0 1 0
CaptureTime Time in seconds before a tag that enters the field is reported. Int 1 120 5
CommandPollInterval The number of minutes between polling for device commands in Jetstream. Int 0 600 60
CommsReboot Number of minutes after the system loses communication that it will automatically reboot. Int 10 1440 230
CommsReconnectInterval Time in seconds to wait before attempting to communicate with Jetstream if there were any communication problems. Int 1 300 10
CommsTimeout Time in seconds to wait for a reply from Jetstream after sending an event or command response. Int 1 300 60
Continuous Set to true for continuous real-time scanning. Set to false to poll the tray periodically for tags. Bool 0 1 1
DNS The DNS to be used in a static LAN environment. When set to '0.0.0.0', the DHCP assigned DNS server is used instead. IP Address 0.0.0.0 255.255.255.255 0.0.0.0
DwellTime Time in milliseconds that is spent on each antenna during continuous scanning. Int 50 5000 200
Gateway The gateway address to be used in a static LAN environment. When set to '0.0.0.0', the DHCP assigned Gateway address is used instead. IP Address 0.0.0.0 255.255.255.255 0.0.0.0
HeartbeatEventInterval The number of minutes between sending a HeartbeatEvent. A setting of 0 will disable HeartbeatEvents. Int 0 600 60
InactivityInterval Time in seconds communications will wait before re-establishing a connection if there is no activity. Int 0 3600 300
IP The IP address to be used in a static LAN environment. When set to '0.0.0.0', the DHCP assigned IP address is used instead. IP Address 0.0.0.0 255.255.255.255 0.0.0.0
JetstreamDeviceUrl The URL to which the tray sends Jetstream messages. String - - us-device.tersosolutions.com
JetstreamWebsocketAppEndpoint The Jetstream resource used to connect for WebSocket communications. Using '#' will disable WebSocket communications. String - - /dwsliveconnection.ashx
LogEntryLevel The verbosity of the logs sent by the tray
  • Off
  • Error
  • Warning
  • Information
  • Verbose
String - - Error
LogFileLevel The verbosity of the logs saved locally on the tray
  • Off
  • Error
  • Warning
  • Information
  • Verbose
  • Trace
  • Debug
String - - Debug
ObjectEventHour The hour to perform the daily system scan as well as other system checks. A setting of -1 will disable ObjectEvents. Int -1 23 0
ObjectEventScanCount The number of times to scan during a GetEPCListCommand or during the daily system scan. Int 1 100 2
ObjectEventScanDelay Number of seconds the tray should wait between scans. Int 1 60 1
ObjectEventScanTime The time in seconds for each scan during a GetEPCListCommand or during the daily system scan. Int 1 300 5
ReaderLogEntryOnFailure Generate a LogEntryEvent when communications to the internal RFID reader fails. Bool 0 1 0
ReaderNumAntennas The number of antennas the tray is using. Int 1 4 4
RemoveEvent Sets whether an aggregate even "remove" is sent when a tag leave the field of scanning. Bool 0 1 0
SearchMode Mode of scanner. Set to 1 for dual target mode to be used by continuous scanning. Set to 1 for dual target or 2 for single target when continuous is set to false for polling. Int 1 2 1
SecureSocket Use secure communications over HTTPS for the tray. Bool 0 1 1
Subnet The subnet address to be used in a static LAN environment. When set to '0.0.0.0', the DHCP assigned subnet is used instead. IP Address 0.0.0.0 255.255.255.255 0.0.0.0
VersionsFileUrl Location of file listing current versions of firmware. Used to configure auto firmware update. String - - http://firmware.tersosolutions.com/versions.json

The list below are some common, potential LogEntryEvents a tray may send in. However, not all possible LogEntryEvents are listed in this table. The LogEntryLevel in use determines which LogEntryEvents are sent to Jetstream.

Name Description
LowFlashMemory LowFlashMemory occurs when the tray has less than 25% flash memory.
LowMemory LowMemory occurs when the tray has less than 25% memory. This event will be sent every hour until the device reboots. Reboot occurs automatically if memory drops to 10%.
NewFirmwareDownloadError NewFirmwareDownloadError occurs when a request to upgrade firmware fails.
ReadException ReadException occurs when there is an issue performing an RFID scan.
Startup Startup occurs whenever the tray is started up.