Enclosures - Firmware v3

RFID enclosures are cabinet, freezer and refrigerator Jetstream devices. They not only support most Jetstream commands and events but extend them by enabling access control and the ability to remotely lockdown.

Name Description Data Type Min Max Default
AggregateEventScanCount Number of times the enclosure should scan after an end user closes the enclosure door. Int 1 10 2
AggregateEventScanTime The time of each individual scan in seconds after an end user closes the enclosure door. Int 0 255 10
Antenna1RxSensitivity The dB receive sensitivity of antenna 1. Int 0 100 50
Antenna1TxPower The dB transmit power of antenna 1. Int 0 100 30
Antenna2RxSensitivity The dB receive sensitivity of antenna 2. Int 0 100 50
Antenna2TxPower The db transmit power of antenna 2. Int 0 100 30
Antenna3RxSensitivity The dB receive sensitivity of antenna 3. Int 0 100 50
Antenna3TxPower The dB transmit power of antenna 3. Int 0 100 30
Antenna4RxSensitivity The dB receive sensitivity of antenna 4. Int 0 100 50
Antenna4TxPower The dB transmit power of antenna 4. Int 0 100 30
CommandPollInterval The number of minutes between polling for device commands in Jetstream. Int 0 255 60
DNS The DNS to be used in a static LAN environment. When set to '0.0.0.0', the DHCP assigned DNS server is used instead. String 0.0.0.0 255.255.255.255 0.0.0.0
DoorOpenTimeLimit Time in seconds the door can be left open before generating a LogEntryEvent. Int 0 65535 300
Gateway The gateway address to be used in a static LAN environment. When set to '0.0.0.0', the DHCP assigned Gateway address is used instead. String 0.0.0.0 255.255.255.255 0.0.0.0
IP The IP address to be used in a static LAN environment. When set to '0.0.0.0', the DHCP assigned IP address is used instead. String 0.0.0.0 255.255.255.255 0.0.0.0
JetstreamDeviceUrl The IP to which the enclosure sends Jetstream messages. URI 0.0.0.0 255.255.255.255 50.16.249.212
LockdownHighTemp High temperature threshold in Celsius to lockdown the enclosure. Int -128 127 127
LockdownOnACPowerFailure Prevent end user access to the enclosure during a power failure event. Bool 0 1 0
LockdownOnReaderFailure Prevent end user access to the enclosure if communications fail with the internal RFID reader. Bool 0 1 0
LockdownOnHighTemp Should the enclosure lockdown when a high temperature occurs? Bool 0 1 0
LogEntryEventHighTemp High temperature threshold in Celsius to send a LogEntryEvent. Int -128 127 127
LogEntryEventLowTemp Low temperature threshold in Celsius to send a LogEntryEvent. Int -128 127 -128
NumberOfAntennas The number of antennas the enclosure is using. Int 0 4 4
LogEntryLevel The verbosity of the logs sent by the enclosure
  • Off
  • Error
  • Warning
  • Information
  • Verbose
  • Trace
  • Debug
String Off Debug Warning
ObjectEventScanCount The number of times to scan during a GetEPCListCommand or during the daily midnight scan. Int 1 10 2
ObjectEventScanTime The time in seconds for each scan during a GetEPCListCommand or during the daily midnight scan. Int 1 10 10
Subnet The subnet address to be used in a static LAN environment. When set to '0.0.0.0', the DHCP assigned subnet is used instead. String 0.0.0.0 255.255.255.255 0.0.0.0

The list below are some common potential LogEntryEvents an enclosure may send in. However, not all possible LogEntryEvents are listed in this table.

Name Description
ACPowerFailure ACPowerFailure occurs when the enclosure loses AC power and is running on battery backup.
ACPowerRestore ACPowerRestore occurs when the enclosure has AC power restored.
AttemptToDeleteUnknownPass AttemptToDeleteUnknownPass occurs when an UpdatePasses DeviceSpecificCommand is executed and a pass in the Remove parameter is not in the enclosure's access control list.
DoorAjar DoorAjar occurs when the door lock is released by something other than the enclosure. For example, someone prying the door open would cause this LogEntryEvent to be generated.
DoorOpen DoorOpen occurs when the door is left open for greater than the DoorOpenTimeLimit.
DoorOpenRestore DoorOpenRestore occurs when the enclosure's door is closed after a DoorOpen scenario.
DoorSensorFailure DoorSensorFailure occurs when the enclosure believes there is a problem with the door sensor.
EventQueueDiskFull EventQueueDiskFull occurs when the enclosure's disk is becoming too full to save any messages in offline mode.
EventQueueDiskRestore EventQueueDiskRestore occurs when the enclosure has freed up enough disk space to work in offline mode.
LowBattery LowBattery occurs when the enclosure's internal UPS battery voltage is less than the 23.0VDC.
NewFirmwareDownloadError NewFirmwareDownloadError occurs when a request to upgrade firmware fails because the enclosure is not able to download the new firmware.
ReadException ReadException occurs when there is an issue performing an RF read.
ScanInterruptionAlarm ScanInterruptionAlarm occurs when someone interrupts a scan by requesting to open the door.
Shutdown Shutdown occurs when the enclosure is signaled to shutdown.
Startup Startup occurs whenever the enclosure is started up.
Temperature Temperature occurs when a Low or High temperature threshold set by LogEntryEventHighTemp or LogEntryEventLowTemp has been reached.
TemperatureRestore TemperatureRestore occurs when the enclosure has gone back into normal temperature range.
UserPassReaderFailure UserPassReaderFailure occurs when the enclosure has lost its connection to the pass reader.
UserPassReaderRestore UserPassReaderRestore occurs when the enclosure has restored a connection to the pass reader.

Version 3 enclosures have at least one, sometimes two, temperature probes installed. A SensorReadingEvent is periodically generated reporting the temperature on the probe(s).

Name Description
TemperatureA The temperature reported on probe A in Celsius.
TemperatureB The temperature reported on probe B in Celsius.